LDI Industries
PRODUCTS | TYPICAL APPLICATIONS | NEWS | VESCOR | FLODAR | HYDRA-TOOL | CONTACT US | SITEMAP



LUBE DEVICES : PRODUCTS : CHAIN OILERS, SPRAY SYSTEMS :
OPERATION SCHEMATIC
BULLETIN F1097-0  
View in PDF format  

OPERATION SCHEMATIC

RVP100 SERIES RESERVOIR, AIR OPERATED / DUAL REGULATORS ONLY

RESERVOIR CONNECTIONS
(See drawing below)

I 1/4 NPTF incoming shop air
II Regulated air to valve - 1/4 NPTF
III Regulated oil to valve - 1/8 NPTF

CAD Drawing

RESERVOIR FEATURES

1. Select capacity. 1 quart to 2 gallon (.946 liter-7.6 liter) polymer.
2. Filler cap.
3. Regulator - fluid pressure 30 PSIG (206.9 kPa) maximum.
4. Pressure gage - fluid.
5. Relief valve - set 30 PSI (206.9 kPa).
6. Regulator - air to spray valve.
7. Pressure gage - 0-30 PSI (0-206.9 kPa) to spray valve.
8. Filter - 40 micron.

SUGGESTIONS FOR SOLENOID OPERATION

CONTINUOUS SPRAY:

  • Wire both solenoids to auxiliary contacts on the "machine" being lubricated.
  • If over-run of liquid can be tolerated when the "machine" is shut down you can simplify the installation by omitting solenoids C and E and replacing the ball valve A with one solenoid valve P/N ESV512 wired to the auxiliary contacts.

    TRIGGERED SPRAY with a rate less than 1O cycles per minute:

  • Wire both solenoids to an electromechanical switch or a non-contact switch which is activated by "machine" movement. Solenoid E for air should be installed as close as possible to the spray valve B.

    PULSED OR TRIGGERED SPRAY with a rate more than 1O cycles per minute:

  • Wire solenoid C for liquid to a repeat cycle timer or "machine" activated trigger switch. Wire solenoid E for air to the "machine" auxiliary contacts so the air flows continuously to minimize droplet formation.

    Do not use a filled fluid such as molydisulfide dispersion, teflon dispersion or any other particle dispersion. They will clog the fine openings of the unit, requiring a total dismantling of the system.

  • ITEM NOT INCLUDED WITH RESERVOIR

    A 1/4 x 1/4 ball valve - shop air shut off.
    B Spray Valve (P/N SV101, SV102 or SV103).
    C Solenoid valve (P/N ESV501) - shut off oil to spray valve.
    D .25 (6.35mm) O.D. semi-rigid or metal as needed, and required fittings.
    E Solenoid valve (P/N ESV501) - shut off air supply valve.



    Home | Products | Typical Applications | News
    Vescor Hydraulic Reservoirs | Flodar Hydraulic Fittings | Hydra-Tool Rotary Manifolds
    Contact Us | Sitemap

    LDI Industries, Inc.
    1864 NAGLE AVE., P.O. BOX 1810
    MANITOWOC, WI 54221
    PHONE: (920) 682-6877
    FAX: (920) 684-7210

    Copyright © Lube Devices, Inc.  
    All Rights Reserved. Privacy Statement